Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
14-7072
OXVIONWEALTH OF PENNSYLVANIA NOTICE OF APPEAL J COURT OF COMMON PLEAS 0-1/4FROM Judicial District, County Of MAGISTERIAL DISTRICT JUDGE JUDGMENT. COMMON PLEAS No. I ���� (� ✓fe NOTICE OF APPEAL Notice is given that the appellant has filed in the above Court of Common Pleas an appeal from the judgment rendered by the Magisterial District Judge on the date and in the case referenced below. NAME OF APPELLANT MAG.DIST.NO. NAME OF MDJ kc ry/via-0 (2011ec-K ADDRESS TY STATE ZIP CODE 1A 11'Tu-n ea In yi-a r—a bKfE7 JUDGMENTI QASF OF(1-taintiff) an an CL -,Ir r, -4- DOCKET No, �7:3�TURE APPELLANT ORA ORNEYORAGENT Ito--T //9—,;Wy This block will be signed ONLY when this notation is required under Pa. XappoMov;Fis—Colimall't (see Pa, R.C.PD.J. No. 1001(6) in action R.C.P.D.J.No.100813. Cm "�-• ` This Notice of Appeal, when received by the Magisterial District Judge, ill before a Magisterial District Judge, A COMPLAINT MUST BE FILED operate as a SUPERSEDEAS to the judgment for possession in this case. within twenty (20)days after filing the NOTICE of APPEAL. Signature of Prothonotary or Deputy PRAECIPE TO ENTER RULE TO FILE COMPLAINT AND RULE TO FILE (This section of form to be used ONLY when appellant was DEFENDANT(see Pa.R.C.P.D.J. No. 1001(7) in action before Magisterial District Judge. IF NOT USED, detach from copy of notice of appeal to be served upon appellee. PRAECIPE: To Prothonotary Enter rule upon C-n ara jI-& ri-L C--k appellee(s),to file a complaint in this appeal Name of appellee(s) (Common Pleas No. within twenty(20)days after service of rule or suffer entry of judgment of non pros. '-'-64gna4wo_pf appellant or attorney or agent RULE: To at Jappellee(s) Na ppelfee(s) (1) You are notified that a rule is hereby entered upon you to file a complaint in this appeal within twenty(20)days after the date of service of this rule upon you by personal service or by certified or registered mail. 'If you do not file a complaint within this time,a JUDGMENT OF NON PROS MAY BE ENTERED AGAINST YOU. (3) The date of service of this rule if service was by mail is the date of the mailing. Pate: ><i 20. I J d Signature of Prothonotary or Deputy ri 0 YOU MUST INCLUDE A COPY OF THE NOTICE OF JUDGMENT/TRANSCRIPT FORM WITH THIS NOTICE OF APPEAL. The appellee and the magisterial district judge in whose effice�the!jUdghnenfwas ir6ndered must be served with a copy of this Notice pursuant to Pa.R.C.P.M.D.J. 1005(A). JA AOPC 312-05 q es a U *3 W31 C- •e F COMMONWEALTH OF PENNSYLVANIA Notice of JudgmentlTranscript Civil COUNTY OF CUMBERLAND Case Mag.Dist.Na: MDJ-09-3-02 Gerald A Snrrick MDJ Name: HiDwable wan I;i<ib!& V. Address: 55 Penn Drive Kenneth Beers Newvft PA 17241 Telephone: 717-774.3187 Kenneth Beers Docket No: MJ-09302-CV-01=119-2014 1235 Newport Rd Ouncannan;PA 17028 Casa Piled: 6nsr�0i4 DEC - 5 2014 Disposition Summary {ct- ulwww) Docket No Dc ndant INisoosition IYwposMion Date MJ-09302-CV-X000119-2014 GamId A 8trriek Kenneth Ekism Judgment for Plaintiff 11/1312014 Judament Summary PartiCiDant tndhriduat LigWM Gerald A Barrick $0.00 $0.00 60.00 Kenneth Beers $0.00 $923.02 $923.02 Jud fled ft J-AP si JudgmerM in The matter of Gerald A Barrick vs. Kenneth Seers on MJ-M302-CV-0=119-2014, on 11/1312fl'14 the judgment was awarded as Io8©ws° bt/Sevar l r:b i* dndivi "liability Deaasit Atoeslisd Aneyurai Cbm iudgtment $0100 $820.52 $820.52 fists 3f5 00 =2-% $102.50 Grand Total $923.02 ANY PARTY HAS THE ArsHT TO APPEAL VWTHIN 30 DAYS AFTER THE ENTRY OF JUDGMENT BY FILING A NOTICE OF APPEAL WITII THE PROTHONOTARY/CLERK OF COURT OF COMMON PLEAS, CIVIL OnIiStON. YOU MUST INCLUDE A COPY OF THIS NOTICE OF JUDGMENTITFrtANSCRIPT FORM VATH YOUR NOTICE OF APPS. EXCEPT AS OTHE[tWISE PROVIDED IN THE RULES OF CIVIL PROCEDURE FOR MAGISTERIAL DISTRICT JUDGES,IF THE JUDGMENT HOLDER ELWTS TO ENTER TRE JUDGIM.NT lit THE COURT OF COMMON PLEAS, ALL FURTHER PROCESS tt WT COME FROM THE COURT OF COMMON PLEAS AND NO FURTHER PROCESS MAY BE ISSUED BY THE MAGISTERIAL DISTRICT JUDGE. UNLESS THE JUDGMENT IS MITERED IN THE COVRT OF C0M360jN PLEAS,ANYONE INTERESTED IN THE JUUGMENT WAY FILE A REQUEST FOR ENTRY IF"T16PACT)ON VVITR TH9 MAGISTERIAL MTRICT JUDGE IF THE JUDGMENT DEBTOR PAYS IN FULL,S€ LMS; OR OTHERWISE COMPLIES WITH THE JUDGMENT. `?- Dare Magisterial DtstrlrrtJudge Vh Ian Coftk COPY pdgrnenL Date UVslenal D;3tJ7ctJ*e MDJS 315 Pap I of 2 Printed.W1312014*5616AM £/I d << 096419g Bn,'6f1 A?-jf1-7tfj7 COMMONWEALTH OF PENNSYLVANIA Rescheduling Notice COUNTY OF CUMBERLAND Mag.Dist.No: MDd-W3-02 QerWd A Barrick MDJ Name: Honorable Vivian COW& V. Andress: 53 Penn Drive Kenneth Beers Newvitle,PA 17249 Telephone: 717-77$3187 Kenneth gears DixAet No: MJ-08342-CV 0=119-zn14 1236 Newport Rd Case Films gjlgt�Q74 Duncannon,PA 17020 Zvi]conloaint has been filed against you in the above captioned terse. A Civil Anion Hearing was previou*scheduled on November 13,2014/ 9:00 AM. It has been rescheduled to be held mat 08te:Thumday,November t3,2014 Piave• Magisterial District Court 09.3-02, Nevwille 56 Perm Drive Time,10-5 Am Newvft,PA 17241 717-77$-3187 Continuance fequested by Magisterial District Judge Vivian Cohidc Reason:Judge Unavailable Notice To Defendant if you intend to amber a defianse to this tomplatnt,you should 96 hatil�this office immediately at the above telephone number. You must appear at the hearing and present your defense. Unliess you do,Judgment may be entered against you by default. If you hm a dalrn against the plaintiff which is within magisterial district judge jurisdiction and which you intend to assert at the hearing,YOU.must life it*0 a complaint form at this office at least five days befbi the date set for the hearing_ Pursuant to Pa.R.C.P.D.J. No. 342(13)(2j m cWm by the defendant vA be permitted in a supplementary action bled for failure d judgment creditor to enter aatisfwHon: NOUC&To Plaintiff Pursuant to Pa.R.C.P.D.J.No.318,you or your attorney will be notified if the defendantgives notice of his/her intention to defond. If free arra stisalllad and raquirse a reasonable accominodaden to gain access 40 Lha MagiafieTW District Court and its services,please contact the Magisterial District Court at the above MOMS or telephone m We are unable to bide tramWortat 1 - Printed:11110/2014 8:39:15AM t-17 .1 •.: !-AAL�f A a- 7^J�ri„stl AA-!A Y-7 iA -21^12 r Geraid A Urrick Docket No,; Add-09302-CV-00 119.2014 V Kenneth Beers Participant List Plaintiffs) Gerald A Barrick 100 Urnekln Road Carlisle,PA 1701$ i*Umh deers 1 M Newpart Rd DuT=nngp,PA 17020 MOJS 315 Page 2 at 2 Pring!:i 911-WO14 110:561BAMl r.tc A SJOSqu81 &O;SD 6Z-LO-ZVU 2012-07-29 05-:03. kenbeers BON >> P 112 Wood Doctor AithorhW Distributor Sales Order Jerry Barrick 100 Limeldln R"d 6rihle,PA 17015 Picone 717-243-3956 Cell 71:7-385-2600 Date, 2-- Z Fax 717254-17.46- r Customer. r•f f.- X11 ' .. E-mai I: ...._. Address: ,� ' ��; s i . ',t.c•�rlr: ,. City: ,�s` .� rs.E'rr ;� 'a-� ,..� State-= ZrP: - Telephone- Cell: Quantity BtO Description M Price/unit Total ke -, l h ffff / �' f J f7) r� t' IIIb f�+ Notes: Subtotal Freight Subtotal+Freight PA Sales Tax t Total Deposit Balance Due ACCEPTANCE: Terms:THE UNDERSIGNO)AGREES TO PAY THE AMOUNT NOTED ACCORDING TO THE TERMS oUTLiNED.Full payment upon delivery or 2%pets inonth after 10 days_All goods property of seller until paid in fill.All sales are final. Pmduct covered by factory warranty only.Please refer to your warranty.For warranty to be activated on furnace purchases,customer must register product with outside Heating Systems Ltd.within 30 days of purchase. Approved: Date: 2012-07-29 05:04 kenbeers 8349803 >> _ P 2/2 { Wood Doctor Anooraoa a�tmter Ates Order - ,ferry Barrick �_ NO Gimeldln Road Carlisle PA 17015 Phone 717243.39% Cell 717.385-2600 Date Fax 717-254-1756 Customer: \1k11 E-mail: Address: : City: _! �,: 't,r:,r �-` .. _ .. ._.State: 100A zTP: '7 4>�•.. Telephone. jf i?�f �' -"� _.Cell. Quantity 8/0 Description Pricefunit Total l U W 141 iL r \ t Notes: x r t subtotal Fmisht z Subtotal+Freight !, ,'` • _,___. PA Sales Tax `7,,:,c:) Total f -7 i , ' r Deposit Balance Due ACCEPTANCE: 'Perms:THE UNDERSIGNED AGREES TO PAY THE AMOUNT NOTED ACCORDWO TO THE TERMS OUTLINED.Full payment upon delivery or 2%per month after 10 days.All goods property of seller until paid in full.All sales mine final. Product covered by factory warranty only. Please refer to your warranty.For warranty to be activated on finnace, purchases,customer must register product with Outside Heating:systems Ltd.within 30 days of pumbase. Approved: Date: KENNETH BEERS, IN THE COURT OF COMMON PLEAS Appellant OF PENNSYLVANIA vs CUMBERLAND COUNTY GERALD A. BARRICK, CIVIL LAW- Appelle DOCKET NO. I Li PRAECIPE FOR ENTRY OF APPEARANCE To the Prothonotary: COMES NOW,Jerry A.Philpott,Esquire,and enters his appearance in this matter on behalf of the appellant, Kenneth Beers. December 5, 2014 Respectfully submitted: Jerry�/Philp0tt;; e9- Supreme Court ID #47624 XV.0.- 227 N. High Street, P.O. Box 116 Duncannon, PA 17020 717-834-3087 IN THE COURT OF COMMON PLEAS CUMBERLAND COUNTY, PENNSYLVANIA 2: COMMON PLEAS NO. 14-7072 CIVIL BEERS V. BARRICK MDJ APPEAL 4{ A PROOF OF SERVICE OF NOTICE OF APPEAL AND RULE TO FILE COMPLAINT (This proof of service MUST BE FILED WITHIN TEN (10) DAYS AFTER filing of the notice of appeal. Check applicable boxes.) COMMONWEALTH OF PENNSYLVANIA COUNTY OF Cumberland AFFIDAVIT: I hereby (swear) (affirm) that I served SS 14-7072 l( a copy of the Notice of Appeal, Common Pleas No. , upon the Magisterial District Judge designated therein on December 12, 2014 (date of service) 20 0 b ersonal service X y (certified) (registered) mail, Gerald Barrck sender's receipt attached hereto, and upon the appellee, (name) , on Decemlgr 12, 2044 personal service❑ XXby (certified) (registered) mail, sender's receipt attached hereto. (SWO FIRMED) AND SUBS RIBED BEFORE ME TH ..JELDAY OF%lc.. , as made COMMONWEAL • ' SYLVANIA NOTARIAL SEAL Jerry Philpott, Notary Public Duncannon Borough, Perry County M mission expires August 02, 2018 Title of off ia My commission expires on v I A , 20 / AOPC 312A - 05 ca r.R ca Cot ph. -,k(P.r.vived IlkoMajlITgryriformatIon visit we alien; MY k :ixii l'ig. "ilrg kill OFFECIAL Postage C3 Certified Fee ci ci Return Receipt Fee a (Endorsement Required) ci C Total Postage & Fees Restricted Delivery Fee (Endorsement Required) C3 a - C3 C:3 C C ci ./` C3 r1 r-4 N r-4 r -g 1=11111111 0 vi N#T Sent To 75Yritel, " t. or PO Box Na: City, State, ZIP+4 5- gat -4.49.c....119211. 1 • ifilklo Postage Certified Fee Return Receipt Fee (Endorsement Required) Restricted Delivery Fee (Endorsement Required) Total Postage & Fees Se 400 J30 UNITE 4-1(1-1.144-4-- O.; 0 Box No. State, Z T• *mt. Agroc,54 arn s E c T I 0 N A S E C T I 0 N Supreme Crt lit Pennsylvania Court'ofrCommon pleas CivilyCove Sheet Ctio a /'..,l►AnrJj County For Prothonotary Use Only: Petition Declaration of Taking Docket No: The information collected on this form is used solely for court administration purposes. This form does not supplement or replace the filing and service of pleadings or other papers as required by law or rules of court Commencement of Action: Petition Declaration of Taking !t Complaint ❑ Writ of Summons ❑ ❑ Transfer from Another Jurisdiction ❑ Lead Plaintiff's N • #1i -p '2Rlt✓c. Lead Defendant's Name: p /Y4rC 7 ties Are money damages requested? 121 Yes ❑ No Dollar Amount Requested: ailwithin arbitration limits (check one) ❑outside arbitration limits Is this a Class Action Suit? ❑ Yes CJ No Is this an MIO Appeal? I2Ei Yes ❑ No Name of Plaintiff/Appellant's Attorney: IA Check here if you have no attorney (are a Self -Represented [Pro Se] Litigant) Nature of the Case: Place an "X" to the left of the ONE case category that most accurately describes your PRIMARY CASE. If you are making more than one type of claim, check the one that you consider most important. TORT (do not include Mass Tort) O Intentional 0 Malicious Prosecution Motor Vehicle Nuisance Premises Liability Product Liability (does not include mass tort) 8 Slander/Libel/ Defamation Other: MASS TORT ❑ Asbestos Tobacco Toxic Tort - DES Toxic Tort - Implant Toxic Waste ❑ Other: PROFESSIONAL LIABLITY ❑ Dental O Legal ❑ Medical ❑ Other Professional: CONTRACT (do not include Judgments) 0 Buyer Plaintiff 0 Debt Collection: Credit Card ® Debt Collection: Other Pihp/i;Jcai.0 orr%r/ ❑ VOV Employment Dispute: Discrimination ❑ Employment Dispute: Other 0 Other: REAL PROPERTY ❑ Ejectment 8 Eminent Domain/Condemnation Ground Rent Landlord/Tenant Dispute Mortgage Foreclosure: Residential Mortgage Foreclosure: Commercial ❑ Partition ❑ Quiet Title ❑ Other: CIVIL APPEALS Administrative Agencies O Board of Assessment ❑ Board of Elections Dept. of Transportation Statutory Appeal: Other ❑ Zoning Board ❑ Other: MISCELLANEOUS ❑ Common Law/Statutory Arbitration O Declaratory Judgment BMandamus Non -Domestic Relations Restraining Order Quo Warranto Replevin ❑ Other: C") rte,: C- C = GERALD A BARRICK IN THE COURT OF COMMON PLEAS OF r'ww `c Plaintiff, CUMBERLAND COUNTY, PENNSYLVAN a rri v. r-- `i c"s KENNETH BEERS, No. 14 – 7072 CIVIL TERM e) - -- rte. { Defendant CIVIL ACTION LAW >, co w• 1 CI --! . N JURY TRIAL DEMANDED - NOTICE YOU HAVE BEEN SUED IN COURT. If you wish to defend against the claims set forth in the following pages, you must take action within twenty (20) days after this Complaint and Notice are served, by entering a written appearance personally or by an attorney and filing in writing with the Court your defenses or objections to the claims set forth against you. You are warned that if you fail to do so the case may proceed without you and a judgment may be entered against you by the Court without further notice for any money claimed in the Complaint or for any other claim or relief requested by the Plaintiff. You may lose money or property or other rights important to you. YOU SHOULD TAKE THIS PAPER TO YOUR LAWYER AT ONCE. IF YOU DO NOT HAVE A LAWYER, GO TO OR TELEPHONE THE OFFICE SET FORTH BELOW. THIS OFFICE CAN PROVIDE YOU WITH INFORMATION ABOUT HIRING A LAWYER. IF YOU CANNOT AFFORD TO HIRE A LAWYER, THIS OFFICE MAY BE ABLE TO PROVIDE YOU WITH INFORMATION ABOUT AGENCIES THAT MAY OFFER LEGAL SERVICES TO ELIGIBLE PERSONS AT A REDUCED FEE OR NO FEE. CUMBERLAND COUNTY BAR ASSOCIATION 32 SOUTH BEDFORD STREET CARLISLE, PA 17013 1-800-990-9108 717-249-3166 1 GERALD A BARRICK, 1 Plaintiff 1 1 KENNETH BEERS, 1 Defendant In the Court of Common Pleas of Cumberland County, Pennsylvania No. 14-7072 Civil Term COMPLAINT AND NOW, Plaintiff, Gerald A Barrick, avers as follows: 1. Plaintiff, Gerald A Barrick, is an Authorized Distributor of Empyre wood furnaces, with a principal place of business at 100 Limekiln Road, Carlisle, Cumberland County, Pennsylvania. 2. Defendant, Kenneth Beers, is an adult individual with an address of 1238 Newport Road, Duncannon, PA 17020 3. Defendant purchased and paid for in full an Empyre Cozeburn 450 outdoor wood burning stove and several unit heaters on October 22, 2012. 4. On the same date, Defendant requested Plaintiff to write a note stating Plaintiff would be present to make necessary connections on the stove on the date of installation by Defendant's contractor even though no labor charges were in the bill of sale. 5. Defendant requested me to bring two sections of chimney pipe, a chimney cap, and two gallons of boiler treatment and necessary connection materials for stove installation. 6. On December 24, 2012, Plaintiff went to Defendant's property to help with the installation with materials/supplies requested totaling $552.26. Sales invoice was submitted prior to leaving on said date. A copy is included and marked as "Exhibit A". 7. Plaintiff has demanded and Defendant has refused to pay the amount due. 8. Plaintiff has fulfilled, performed, and complied with all obligations requested for installation of the stove. 9. Plaintiff has been awarded a Notice of Judgment/Transcript Civil Case from Magisterial District Justice Vivian Cohick on November 13, 2014 in the amount of $923.02. A copy is included and marked as "Exhibit B". COUNT I - BREACH OF CONTRACT 10. Plaintiff hereby incorporates by reference the averments contained in Paragraphs 1 through 9 of this Complaint. 11. Defendant has breached the expressed and implied obligations, conditions, and terms of the contract by failing to pay the amount due to the Plaintiff. WHEREFORE, Plaintiff demands judgment in the amount of $923.02, plus interest, and cost of suit. COUNT II - UNJUST ENRICHMENT 12. Plaintiff hereby incorporates by reference the averments contained in Paragraphs 1 through 11 of this Complaint. 13. Having requested Plaintiff to provide merchandise and provide services, and the Plaintiff doing so to the benefit of Defendant, Defendant became liable to Plaintiff for said service. 14. Defendant has been unjustly enriched by accepting said services without paying Plaintiff a reasonable compensation. 15. The total amount by which the Defendant has become enriched is $923.02. WHEREFORE, Plaintiff demands judgment against Defendant Kenneth Beers in the amount of $923.02, plus interest, attorney's fees, and costs of suit. Dated this 22nd day of December 2014. Gerald A Barrick, Plaintiff &i4rI-4 Wood Doctor® Authorized Distributor Jerry Barrick 100 Limekiln Road Carlisle, PA 17015 Phone 717-243-3956 Cell 717-385-2600 Fax 717-254-1756 Customer: ", 1:-_('�"<:' E-mail: Address: i..t;,,,; r > . Sales Order Date City: Telephone: ( -> Cell: ZIP: Quantity l6/0 Freight 1 `v £r. Description °u Price/unit Total 4 <'z Total moi, .;f'% t-, l ./ r ,, /; C C .„�: -i' �,, 1:; I , n '- , ' ,,, . 1 ' .. ..' 1 .1 �..% . 1 .✓ )/ L ; .If !.g . �1 -j .. l�. { 4 Ili., l.'J� :.J -� f Y .� .f a , L: ,it 1 � tt r f !i Z ) ...ice. 1 �� ..,. Jr < ` -7'r, r'rL' h.':; ,fie, iLA 4 t.,. .l ,%yle:t is a,^ .:. e; ,r-%7 G t. , - Wf a . y,r' Notes: Subtotal j Freight 1 `v £r. Subtotal + Freight °u PA Sales Tax 4 <'z Total :575'2 2- 4 Deposit Balance Due ACCEPTANCE: Terms: THE UNDERSIGNED AGREES TO PAY THE AMOUNT NOTED ACCORDING TO THE TERMS OUTLINED. Full payment upon delivery or 2% per month after 10 days. All goods property of seller until paid in full. All sales are final. Product covered by factory warranty only. Please refer to your warranty. For warranty to be activated on furnace purchases, customer must register product with Outside Heating Systems Ltd. within 30 days of purchase. Approved: Date: COIVIMONVVEA.LTH OF PENNSYLVANIA :;AUNTY OF CUMBERLAND Dist. No: MDJ-09-3-02 INID..! Name: Honorable Vivian Cohick caress: 55 Penn Drive Newville, PA 17241 ei; phoney 717-776-3137 Gerald A Barrick 100 Limekiln Road Oariisie, PA 17018 Notice ofdgmlentlTranscr ;t C vN Case Gerald A Barrick v. Kenneth Beers Docker No: MJ -09302 -CV -0000119-2014 Case Fled: 9/16/2014 Disposiion Summary (cc- Cross Complaint) :Joc, ei Ivo Plaintiff Defendant Dis.00sition Disposition Date i'vu-0 13,02 -CV -0000119-2014 Gerald A Garrick Kenneth Beers Jud.iment for Plaintiff 11/13/201,1 Juacgment Surrirnary Participant Joint/Several Liability individual Liability Amount 3eraid A Barrick $0.00 $0.00 $3.00 Kenneth deers $0.00 $923.02 2923.02 judgment Finding cPost Judgment) In the matter or Gerald A Barrick vs. Kenneth Beers on MJ -09.302 -CV -0000119-2014, on 11 13/2014 the judgment was awarded as ioilo+:vs: Judgment Component Joint/Several Liability Individual Liability Dept:>it Applied Amount Civil Judgment 20.00 $820.52 $820.52 Costs $0.00 $102.50 $102.50 Grand Total• $923.02 ANY PARTY HAS THE RIGHT TO APPEAL WITHIN 30 DAYS AFTER THE ENTRY OF JUDGIVIENT BY FILING A NOTICE OF P,PPEAL WITH THE PROTHONOTARY/CLERK OF COURT OF COMMON PLEAS, CIVIL DIVISION. YOU MUST INCLUDE A COPY OF THIS NOTICE OF JUDGiu!ENI7TRANSCRIPT FORM WITH YOUR NOTICE OF APPEAL. EXCEPT AS OTHERWISE PROVIDED IN THE RULES OF CIVIL PROCEDURE FOR MVIAGISTER1,-:L DISTRICT JUDGES, IF TF;:. JUDGMENT /OLDER ELECTS TO ENTER THE JUDGMENT IN THE -COURT OF COMMON PLEAS, ALL FURTHER PROCESS MUST COME FROM THE COURT OF COMMON PLEAS AND NO FURTHER PROCESS MAY BE ISSUED BY THE MAGISTERIAL. DISTRICT JUDGE. • UNLESS TI -IE JUDGMENT IS ENTERED IN THE COURT OF COMMON PLEAS, ANYONE INTERESTED IN THE JUDGMENT MAY FILE A REQUEST FOR ENTRY OF SATISFACTION WITH THE MAGISTERIAL DISTRICT JUDGE IF THE JUDGMENT DEBTOR PAYS IN FULL, SETTLES, OR OTHERWISE COMPLIES WITH THE JUDGMENT. Date 1. agisterial District Judge Vivian Cohick 1 certity that this is a true and correct copy of the record or the proceedings containing the judgment. Date Magisterial District Judge IIDJ S 315 - Page 1 of 2 Printed: 11/13/2514 10:56:1 SAM GERALD A. BARRICK, Plaintiff vs. NO: 14-7072 • Defendant CIVIL KENNETH BEERS, IN THE COURT OF COMMON PLEAS FOR CUMBERLAND COUNTY, PENNSYLVANIA NOTICE To: Gerald A. Barrick 100 Limekiln Road Carlisle, PA 17015 You are hereby notified to file a written response t Answer within twenty (20) days from service hereof of a judgment may be ent. u. January 9, 2015 re 27 N. gh Stre, P.O. Box 116 Dunca o 17020 717-834-3087 GERALD A. BARRICK, Plaintiff vs. KENNETH BEERS, Defendant IN THE COURT OF COMMON PLEAS FOR CUMBERLAND COUNTY, • PENNSYLVANIA • NO: 14-7072 CIVIL ANSWER COMES NOW the above defendant and answers plaintiff's complaint as follows: 1. Admitted. 2. Admitted. 3. Admitted, but for reasons given in the New Matter, defendant was led to believe that the stove included a chimney, among other features. 4. Admitted. See New Matter for more details. 5. Denied. Defendant asked plaintiff to be present to install the wood stove and naturally expected him to provide the parts shown in the brochure and instructions as part said installation. 6. Admitted. 7. Admitted. 8. Denied. See New Matter for what plaintiff did wrong. 9. Admitted, but irrelevant. Defendant has appealed the District Justice Judgment, as is his right. COUNT I - BREACH OF CONTRACT 10. Defendant hereby incorporates by reference the answers given in Paragraphs 1-9 of this Answer. 11. Denied. 1 COUNT II - UNJUST ENRICHMENT 12. Defendant hereby incorporates by reference the answers given in Paragraphs 1-9 of this Answer. 13. Denied. Plaintiff contracted to provide a wood stove as shown in the advertising brochure and installation instructions. Plaintiff is trying to charge for features that were clearly included in the base price. 14. Denied. 15. Denied. NEW MATTER 16. Plaintiff advertized a Cozeburn 450 wood burning stove in a brochure. Attached hereto and incorporated herein by reference as Exhibit A to this Answer is that brochure. 17. The pictures of the Cozeburn stoves in Exhibit A all show chimneys. 18. The specification of the Cozeburn stove in Exhibit A includes "Chimney size 8". 19. Plaintiff furnished to defendant a Cozeburn Installation and Operating Instructions pamphlet with the installed stove. Attached hereto and incorporated herein by reference as Exhibit B to this Answer is that pamphlet. 20. All of the pictures the Cozeburn stoves in Exhibit B show chimneys. 21. The "suggested material required to complete an installation" on page 9 of Exhibit B does not include a chimney. 22. The maintenance procedures in Exhibit B at page 20 say "Check and clean the chimney at least once per month." 23. When defendant ordered and paid for the Cozeburn 450 he undertook to dig his own trenches and install the underground pipe. However, he understood that plaintiff would make the hook-ups as part of the sale price. That is why he demanded a note clarifying that plaintiff would be present to make the necessary connections on the stove on the date of installation by defendant's contractor even though no labor charges were in the bill of sale, all as alleged by plaintiff in the complaint at Paragraph 4. And, plaintiff's Exhibit B does not charge for labor. In fact, it expressly states "Labor - N/C". 2 24. Defendant expected the stove to be installed exactly as shown in Exhibits A and B, including a chimney. 25. Plaintiff's Exhibit B charges defendant for the chimney and the materials needed to hook up the chimney. Defendant contends that all of these expenses were included in the installation of the wood stove as plaintiff had undertaken to do. Defendant refuses to pay extra for items that are part of the basic package as advertized. WHEREFORE, defendant respectfully demands that plaintiff's complaint be dismissed with prejudice. Dated: January 9, 2015 3 espectfull submitted; Jer A. Ph . High St ►r uncannon, 717-834-30 Attorney for defendant 7 , Esquir , P.O Al ox 116 I verify that the statements made in the foregoing document are true and correct to my best personal knowledge, understanding, information and belief. I understand that false statements herein are made subject to the penalties of 18 Pa.C.S. § 4904, relating to unsworn falsification to authorities. PROodiABoUs�► pYRE► High (1uaGty outdoor Wood . SAFE OUTDOOR HEAT SOURCE . HIGH OUTPUT BOILER • SAVE MONEY ON FUEL AND INSURANCE • HEAT WITH RESOURCES RENEWABLE RESOURCES • HEAT YOUR HOUSE, S POOL, DOMESTIC N 01. WATER AND MORE. EXHIBIT A Y rev ' '14�'� The Empyre Up Close • 1 Stainless Steel Chimney Insulated and double walled to reduce condensation. 2 Floating Water Level Indicator Eliminates pressure and evaporation. 3 Heavy Duty One Piece Roof Leak proof to protect your boiler from the elements. 4 Top Lifting Hook For easy installation. 5 304L Stainless Steel Construction Laser cut components and solid steel construction for quality and longevity. 6 Fiberglass Insulation For safety will not dry out, shrink, crack or ignite. 7 Exterior Light For night wood loading. 8 Digital Control Panel With easy to read temperature and water level indicators. 9 Large Capacity Water Jacket Pressure and die tested for fast heat recovery. The Empyre Outdoor Hot Water Boiler is ideal for heating houses, shops, small greenhouses, pools, hot tubs, garages, sheds and domestic hot water. The Empyre is designed to connect directly into your existing heating system. The Empyre's central firebox is enclosed by a large capacity water jacket. The top of the firebox is corrugated to provide maximum surface area for the most efficient heat. Once the water is heated, it is channeled to your home's heating system through insulated underground pipes. The hot water from the boiler may be used for several applications in your home. The hot water line is typically connected to your hot water tank through a heat exchanger, providing all your domestic hot water. The water is then channeled into the existing radiant or forced air heating system. A water -to -air heat exchanger can also be installed to direct the heat into your heating system. The Empyre is installed in conjunction with your existing heating system, which remains connected as a backup system. Heat is thermostatically controlled on the boiler by setting the aquastat to the desired temperature, ensuring even, consistent, efficient heat. The Empyre is equipped with multiple hookups, allowing you to heat several buildings at once. 10 Corrugated Firebox Top Maximizes heat transfer and efficiency. 11 Baffle Ports Increase heat transfer and combustion efficiency and reduce smoke when opening the door. 12 High Temp Insulated Door Pressure touch handle provides a firm seal and automatic solenoid damper or front air reducer improves combustion efficiency. 13 Firebox Large firebox capacity. 14 Water Filled Grates Located below firebox to maximize heat transfer and combustion efficiency. 15 Full Length Ash Pan For simple and convenient cleaning. 16 Forklift Guides For easy lifting, moving and installation. 17 Legs Raises the firebox for easy loading. 18 Insulated Rear Hookup Cover Provides easy and safe access for pipe hookup. 19 Insulated Chimney Door For easy access chimney cleaning. The Cozeburn Outdoor Hot Water Boiler has been keeping families warm since 1989, using natural renewable resources. By using high quality components, you can be sure of years of great performance and reliability. The entire firebox and water jacket is manufactured using top quality steel with fibreglass insulation ensuring maximum heat output. The firebox is specifically designed and tested for maximum heat transfer efficiency and is able to withstand high temperatures. The large capacity water jacket provides fast heat recovery. Water circulating around the firebox and through the water filled grates maximizes heat transfer which improves efficiency. All boilers are pressure and die tested for quality assurance prior to leaving the factory. Features include a full length ash pan The Empyre and Cozeburn are ideal for heating greenhouses. Hot water can be pumped from the boiler to forced air heaters on the ceiling as well as into radiant heating in table tops. ...::i:_n`►ifa; With hot water flowing through tubes in the floors of your house, in -floor heating is the most efficient, consistent and comfortable heat to enjoy. Hot water from the boiler flows through a heat exchanger on the existing hot water heater. POU+ OK SPA With the multiple hookup option, the Empyre or Cozeburn can provide heat for your pool or spa with pipes connecting directly to the existing pool heater. making ash removal easy. An eye level digital control panel has a clear readout allowing for accurate temperature adjustments. For safety, the Cozeburn Outdoor Hot Water Boiler has a large firebox door for ease of loading, high temperature insulation which eliminates hot areas, and a night light for additional visibility for nighttime loading. Because the Cozeburn boiler is a non pressurized system it provides a safe environment for you and your family. By meeting all requirements of CSA and UL, you can be rest assured that the Cozeburn will provide affordable quality, performance and reliability for your heating needs for years to come. ????R tXlzZ7lllIlNallaa??1I UUUUUUUkiU 3'IULi ]PLE buILUIr1G HOOKUP Multiple connection ports on the Empyre and Cozeburn allow you to heat several buildings such as a pool, greenhouse or shop with a single heating unit. Feature Benefits TOP GRADE STAINLESS STEEL CONSTRUCTION` Quality workmanship means nothing without quality materials. By using top grade 304L Stainless Steel, Pro -Fab Industries ensures the longevity and quality of your boiler. The stainless steel firebox must be able to sustain intense heat without cracking or breaking. 304L is the stainless steel used by Pro -Fab Industries for superior workmanship and longer product life. With a low carbon and high alloy content, 304L is less likely to rust or crack after welding. It has a higher ductility than other stainless steels, providing more flexibility and greater durability. With 50% more nickel and 80% more chromium than 409SS, 304L is the highest stainless steel grade and quality used in the outdoor boiler industry. Boilers manufactured from 304L Stainless Steel are built to last. The added protection against rust and corrosion offers the security of a long lasting low maintenance boiler. *Refers to Empyre boilers Specifications Steel Type fetk Et" Body Width frOg1l_•.ntif� Body Length Chimney Size If CPW,250 EMPYRE FULL LENGTH ASH PAN The full length ash pan makes ash disposal easy and clean. No brushing or awkward, messy shoveling necessary. HIGH OUTPUT, LOW EMISSIONS Pro -Fab Industries is dedicated to producing the most efficient alternative energy boilers on the market. In addition to efficiency, Pro -Fab Industries is committed to protecting the environment by continually reducing emissions from its boilers. Pro -Fab Industries' in-house testing lab tests and analyzes fuels and boilers to determine the highest output with the lowest emissions. Output and emissions vary based on fuel quality, • location and boiler size. Talk to your dealer for more information. 11111111111111111111111111111111111111111111111111 g k' 301L 1O1E1 STEEL 'CPW 450 304 Stainless 47"'~ 59" 6" I250 MS 304 Stainless 55" 77" 8" rte_ Mild Steel 47" 59" 6" 450 MS Mild Steel 55" 77" Firebox Size -.1A/ x H x L 30" x 33" x 42" 36" x 45" x 60" 30" x 33" x 42" 36'• x 45" x 60" • 1 Max Heating Area (sq. ft.) 2,000 - 4,000 AIM sk: Limited WARRANTY 20 year Pro -Fab Industries Inc., founded in 1989, is North America's premier designer of alternative heating products. With five manufacturing facilities across three countries, Pro -Fab Industries has the widest range of EPA qualified clean burning units on the market. 6,000 - 8,000 2,000 - 4,000 6,000 - 8,000 !. .� •I F. 20 year 10 year 10 year 13t.AB INDUSTRIES INC. INC Manufactured by: Pro -Fab Industries Inc. Arborg, MB, Canada ROC 0A0 888-933-4440 www.profabgroup.com f,'. Your EMPYRE Dealer Part No. 817974R00 Printed in Canada JW0512 EXHIBIT B Cozeburn Outdoor Hot Water Wood Furnace 10 YEAR LIMITED WARRANTY REGISTRATION FORM Pro -Fab Industries Inc. (hereinafter called "Pro -Fab") warrants to the original owner of the Cozeburn Furnace (hereinafter called the "Cozebum") the following: A two (2) year warranty on the workmanship of the furnace and workmanship on all parts manufactured by Pro -Fab, including Pro -Fab manufactured owner -serviceable parts (provided such parts are serviced in accordance with the Operator's Manual), from the consumer date of purchase, and excluding normal wear items such as (but not limited to) the door gasket, fire brick (if applicable), insulation, exterior finish and chimney. A one (1) year warranty for any labour required for any repair or replacement of the furnace or parts from the consumer date of purchase based on Pro-Fab's predetermined labour rates and allowable hours. A limited pro -rated warranty coverage (which Includes the one (1) year labour coverage at Pro -Fab rates and hours as stated above) for a defective firebox and water jacket only, based on a pro -rated scale from the consumer date of purchase. Absolutely no warranty is provided after ten (10) years from the consumer date of purchase. See back of Installation and Operation Instruction Manual for complete warranty details. A signed Warranty Registration Form must be received by Pro -Fab within 30 days of purchase, along with a copy of the original purchase invoice from the dealer completing the sale transaction. Mall to: Pro -Fab Industries Inc.,,Box 112, Arborg, MB ROC OAO Customer Name: Ae ri ;, I'S Address: _ / 7 /1/G' D a'1 u v . City: // r..en rn S C' a -t - - Prov/State: ,/ A Postai Zip: / —7°2-4 Phone No: —2/ 2 C. V 'd-- L fj G q Dealer. X d.-2 get.' t i Address: /e/- 14/►i,'//. /_ City. ire'r /#1-4 Prov/Slate: // Postal/Zip: / 7 U / Phone No: 7/7 2113 - 9S 20 Email Address: Email Address. LY%Y. ri k'r- (f- re/met"; /u Model No: Serial No: C � s -v ?i 5- 7 1/s JS r5//-- /rJS Date Purchased' /a hi /2r/ Check One: 0 Commercial Residential l Farm ❑Other DEALER CHECKLIST IAII warning decals are In place, clean and legible. E i Customer has been Instructed to review safety and operating procedures with all operators annually. I have thoroughly inspected the Cozebum Outdoor Wood Furnace and made adjustments and corrections as needed. ❑ Customer has Pro -Feb approved water treatment. Options Provided ❑ Front Draft Natural ❑ Front Draft - Forced have instructed the customer on the above described equipment and reviewed f nonce, safety operations and applicable warranty. inspected By ! !I Installation and Operation Instruction Manual, assembly, meinto- Dealer's Signature / 0/2 2. Date CUSTOMER CHECKLIST ❑ I have received, read and understand the Installation and Operation Instruction Manual completely. ❑ I understand that water quality is Important in the furnace as referenced in the Installation and Operation Instruction Manual. ❑ I agree to burn wood only and follow the maintenance procedures as sot out In the Instalialion and Operation Instruction Mnnual. o I have enclosed a copy of ray sales receipt Indicating the date of purchase. r have received end nevrewed the above Installation and Operation instruction Manual and 1 have been Instructed es to the care, adjustments, safety operatlon and applicable warranty of the unit purchased. 7 . /e1» // Owner's Signature Date White - Pro -Fab Yellow - Customer Pink - Dealer May 2012. 815378R03 TABLE OF CONTENTS Introduction 3-4 The Cozeburn Outdoor Hot Water Wood Furnace 3 Model & Serial Number Information 4 Safety 5-7 Safety Precautions.. 5 Safety Alert Symbol 6 Signal Words 6 Safety Decals 7 Features 8 Indentifying Main Components 8 Installation 9-16 Suggested Material Required to Complete an Installation 9 Site Requirements 9 Foundation Dimensions 10 Trench for Underground Pipes 10 Installing the Furnace 11 Typical installation 12 Hookup to the Existing Heat System (Water to Air) 13 Belt Driven Hot Air Fan 13 Direct Drive Fan 13 Thermostat 13 Under Floor Heat 13 Side Arm Installation 14 Optional Heat Exchanger 14 Auxiliary Heat (Water to Water) 15 Hookup with Existing Indoor Furnace (Water to Water Plate Heat Exchanger) 15 Baseboard Distribution 16 Pool & Spa Hookup 16 Common Header Set Up 16 Operation 17-19 First Fill 17 Maintaining Proper Water Level 17 Starting the Fire in the Outdoor Hot Water Wood Furnace 18 Outdoor Best Burn Practices 19 Maintenance 20-21 During Heating Season 20 End of Heating Season 20 Cleaning the Ash Tray 21 Power Outages 21 COZEBURN INSTALLATION AND OPERATION MANUAL 1 TABLE OF CONTENTS Reference 22-25 Operating the Digital Temperature Switch (DTS). 22 Outdoor Hot Water Wood Furnace Wiring Diagram - CPW 250 & CPW. 450 23 Furnace Reference Chart 24 Forced. & Natural Draft Door 24 • Furnace Specifications Troubleshooting 26-27 Furnace Troubleshooting 26 Digital Controller Troubleshooting 27. Warranty 28 25 2 COZEBURN INSTALLATION AND OPERATION MANUAL INTRODUCTION The Cozeburn Outdoor Hot Water Wood Furnace You have selected one of the best outdoor wood furnaces on the market today! It has been designed and built to old fashioned standards, and we are proud to offer a 10 year limited warranty! To ensure maximum benefit from your new Cozeburn furnace, it is suggested that the Installation and Operation Instruction manual be read from cover to cover and all instructions followed carefully. The Cozeburn furnace has been designed for outdoor installation and is ideally suited for both domestic and industrial use. Please keep this manual for future reference. 250MS & 450MS (MILD STEEL) COZEBURN INSTALLATION AND OPERATION MANUAL 3 INTRODUCTION Model & Serial Number Information Locate and record the model number and serial number in the space provided. See page 7 (item #3) for location of decal on furnace. Have this information available when contacting the dealer for service, warranty or other information. COZEBURN Ontdoor%naked Hydeodc Deateliaduniffintlr Mildew De %odfred Hydtonk IQOIAA9P13NO isanamvainvitm DE Ninth r iaWan. OEOY11FOIOE CSAMINI ODKIES14131 =mower I101ae OE 'ACM MEM= lin UM MITIONE OE Rai. MOM 9910E OIC aeta3te Wits leg 3IMAM%3zeegeelm Mow leepipeful lopp aaae/f oladwed nein- nasedesele;m wstesNee nil Ral -Um main* maeltpasaetn Wei eselag owienere arrigetneeile mem eaaeoomosadrodedeor nes meet®tRRtoC ateaSWUM. OM a., belerila eseibreerieeesel • gel lig Imo awl LIMN dorler n+drlebpaenmaao laAftil, angbfOfn nalee�ta. liemaeeeellfaebtelaemane wept wpm amino; dessoorer a ado etmolt®f ltemeeti.rnsnael iemode atebtle Indere ltTfenew estOdYe eeae doe m been eueq► r Mos SW0 Wen fess SSW 11111neeslewn Reopen stedosedosoltierld ,enabmMPpRena Re¢ • emeeassisrailegarez 22133MEmt ernrel.aee; es W OLIO 'WO mesaaerie erece iprbetelet: Ora -Wens ooresided boalla neteeroaeprakeemm Wen: commtee.ttmand etareef 1105eaeepn et • over > edea einNimuereerepaintisaremes mpeaOhl de Woodeameee. aeuee.emmos imoo •wpas monde rob desrdestedtasmgerm pew mew elel lb' no M weer reedendO se also en Pen e d onto IP laeae4ald+set! ttea easemsaponereDaceeseaImotheoeoa•*piso eoloeaeMisildeL Ieteeseie pet LeaElevMb trasat Ito apprelw m eliteep eY tail eller eeaiateae tee toe Jo mow 22asad5eseMEMO lemrdoeina)moo coo sass Mow emeei Wolin oleo GIeeattiae-Mbde d oom otereemodisio smaepa pal enpunted. Oleo tap* fewee,Seanppear eslilisode Ingo Men cage, deOwe& tealoperas ilminaemi sleet Q om mnesel ep rshoeperromrmamdgemoo li o CI US wercaa parReltaeusr>am 4 COZEBURN INSTALLATION AND OPERATION MANUAL 1 r," r rrn SAFETY • The Cozebum furnace is ; designed to work • in conjunction with another heat source. We recommend this furnace not 'to. be used •as a stand, alone unit, .Should the system fail or'run7.out Of •wood, a'backupsystem should be in placer • For best efficiency and cleanest 'bum use only seasoned fire wood. NEVER burn trash; tires, solvents, plastics, gasoline, engine oil or other • flammable liquids, rubber,:' naptha, -household garbage, material treated .With petroleum products (particle board, railroad ties and pressure treated, painted, (*kiln dried wood), leaves, paper products,. or.cardboard. Start the.. fire with paper and �smoll kindling • • 'The Cozebutri furnace is designed:for outdoor' use only. NEVER install the• Cozeburn furnace indoors. • Keep area around the furnace clean at all times to. avoid possible lire hazards.Adhere to installation clearance and: restrictions. . • The Cozebum: rear access door is *equipped with a latch locking. bolt. Because of an electrooution hazard and hot surfaces keep children, away. ALWAYS secure door With: iatch locking boll and tighten bolt with:wrench. • Read the manual carefully and read all decals on the Cozebum furnace.' Should you have any questions not answered in this manual, contact your dealer. WARNING: EXPLOSIVE GASES Gases formed during solid -fuel combustion may cause a small explosion when the furnace is refueled. Door Opening Instructions: 1. Switch blower off. 2. Stand back behind door. 3. SLOWLY open door: 4. Wait for smoke to clear (30 seconds). Close door if smoke continues. 5. Open door fully. 6. After loading, always close and latch door firmly. 7.. Switch blower on. • CAUTION! . Keep children a -safe distance from the furnace.. . • DO. NOT use -chemicals,• gasoline. oil or any,other combustible .fluid to start the fire. • • • *DO NOT store fuel :or combustible: materials within . the installation clearance area.. I ' . • • DO NOT connect the unit to a chimney flue that,. serves another appliance. • • : DO; NOT burn trash in this furnace.. ;;DO ;NOT pressurize water infurnace. • DO.NOT damage: furnace. Load wood carefully., • DO NOT run furnace with waterlevel below add mark. . • DO NOT dump. ash close to any'combustible materials. • • DO NOT operate with loading or ash removal - doors open.. • DO NOT add fuel during a power outage. • • DO NOT allow, ash -and creosote buildup. Furnace •muSt:be.kept.in good condition.: Follow cleaning • instructions In the Installation and Operation Instruction Manual. . • •. • •DO.NOT modify this unit in any Any Modification will void the warranty in the ,eireht of loss,of.electrical power. •1. Opehall•ftoW=check and zoneva1ves In the system.'. :Depending on system design,°:.this may allow convective circulation. • • • 2. It important to.remember'that the heating system cannot dispose of a great deal: of heat without the circulators •running. Avoid : overfiringl, .. DO NOT LOAD LARGE AMOUNTS OF SOLID FUEL INTO THE .FURNACEI Fire the `furnace cautiously' until. It is . determined how quicidy the heat system is able to dissipate. the .heat being,.produced by tide • furnace. • 3'. ; When:3he power has; returned,;, reset all:flow=check and zone valves and resume •normal operation of the system. • • • In the event of a runaway fire: : 1. Make sure the firebox door is tightly, closed. 2. Close all the combustion. air.' Inlets: on the furnace.. To' cool an 'overheated furnace:: 1. Tum all thermostats in the house to their highest temperature setting. COZEBURN INSTALLATION AND OPERATION MANUAL 5 SAFETY Safety Alert Symbol Signal Words The Safety Alert symbol identifies Note the use of the signal words: DANGER; :. important safety messages in the WARNING and CAUTION with the safety • manual and on the furnace. When messages. this symbol is present, be alert to the possibility of injury or death. Follow all The appropriate signal word has been selected the instructions in the safety message given. This symbol means attention, be alert, and your safety is involved. Why is SAFETY important to you? Three very important reasons: 1. Accidents disable and kill. 2. Accidents cost. 3. Accidents can be avoided. using the following guidelines: O DANGER DANGER: Indicates an imminently hazardous situation that, if not avoided, WILL result in death: or serious injury if proper precautions are not taken. WARNING: Indicates a potentially hazardous situation that, if not avoided, COULD result in death or serious injury if proper precautions are not taken. ttl i' F CAUTION: Indicates a potentially hazardous situation that, if not avoided, MAY result in minor or • moderate injury if proper practices are not taken,. or serves as a reminder to follow appropriate safety practices. COZEBURN INSTALLATION AND OPERATION MANUAL .r.' r r I I r r L r r r SAFETY Safety Decals Please read and follow directions to ensure safe practices when using the Cozeburn furnace. 1) DOOR AREA MAY BE HOT. OPEN DOOR SLOWLY. CLOSE DOOR PROPERLY - Located on left hand side of damper. 2) MAX. WOOD FILL TO TOP OF DOOR. - Located on top left hand corner of front door. 3) Furnace Serial Decal - Located on left hand side of furnace. 4) NOTEI MINIMUM 6 FT. OF INSULATED CHIMNEY IS REQUIRED FOR PROPER DRAFT. CLEAN CHIMNEY OUTLET REGULARLY. COVER CHIMNEY WHEN FURNACE IS NOT IN USE. - Located left of the chimney cover. 5) THIS LID IS HEAVY. USE BOTH HANDS. - Located on back chimney cover. 6 6) OUTDOOR BEST BURN PRACTICES - Located on the right front corner. (For further details see page 19.) 1. ACAUTIONI •Door area may be hot. • Opon door slowly. • Close door property. ,AATTENTIONI • La region de paste paw tiro anode. • Ouweris Parte lento/nom. • Porte Stroke eomtte hint. 2. MAX.WOOD FILL TO TOP OF DOOR SUFFISANCE EN BOIS MAXIMUM AUSOU w Dt=SUS DE LA PoalE 4. Note! •/u•Irm.Ake. rwbdd Mom, la `.° tot peps, drew *Cam dttemerattla •[orrdmemrr/r bowels set la K Note! •redsKd•bshallot* WW1.•• aloe r•aa► ••Wwr•• eigullimassa • Ceram Cs theadtae kw Wag thrrat OUTDOOR FURNACE BEST BURN PRACTICES r...•r.r.•r••... •-. ▪ W.• lYr.••..•.a••r.••r...•.•r •••••.a...•.r-•..-.• •••••••0“1.1,1•••••••••••••••• ▪ wpgr sem soda.... 4.14.1•41.1041••••••14.10, :.::a :_ •f•Mq 1. or WE Wrr• .....•...•. - ods. -s. •.•r»ur.rr-.•..w •.... ..••. Or••.r r• r .•.r1.•.4111•00....1Mt ✓ ows •..y..w. ww.e• r. • Wookh••.. rIS... NW •..r• wlorr••.mrr.r .••�rrar•`ri.•�r.n • • r▪ .:w•M...rw~••�rr .• Malmo Ilmohooffp•modlo a...•...............r.. LES FRAMES DE BROLAGE LES PLUS EPFICACES POUR LES FOURNAISES EXTERIEURES u▪ ommas Oftwoo• goof. • 1...••.Ow-.*- •NM W.4..MW+•.-4r .. ••,. ww • trod.••{.. • \ . ••• • •ww••......•..-..-. -sods YY.•...s.•.INr••• rM.w ooso, omfoogoom ...owe loom. •w.rrM manor. of �_r.r1r Y.•••••.•• . s+•...•nw.•rrr rr•• rano* of boomodoOlh000lio. ••••• ▪ or spoofratotopo oaf rar.r•.mer.o..r•- RMq• MILOWq �•••aru.wrq.e.. „r COZEBURN INSTALLATION AND OPERATION MANUAL 7 FEATURES Indent' Mg Main Components 1:.t...-" .i.n.....,54`3"_'!;.. ): u 706* v.'. 11a -';.'liiir 1 Insulated Chimney 11 Forklift Lifting Guides 2 Light : 12 Legs 3 Light & Power Switch, Manual Reset Breaker 13 Rear Access Cover 4 Aquastat and Thermostat 14 Drain 5 Control Panel Cover 15 Junction Box 6 Loading Door . 16 Supply/Return Hookups 7 Solenoid & Blower :': ... (behind cover) • .17 . :.... Chimney Clean Out'..:. Cover' 8 Damper (behind cover) ' 18 Roof 9 Pressure Touch Door Handler 19 Top Ufting Hook 10 Removable Ash Try 20 Vent & Water Level Indicator 8 COZEBURN INSTALLATION AND OPERATION MANUAL P INSTALLATION Suggested Material Required to Complete an Installation For the installation of a single family residential hookup with the furnace approximately 50 feet (15.24 m) from the building to be heated, the following will be required: a. Cozeburn Outdoor Wood Stove (furnace) b. Concrete pad for furnace base c. 150 feet (45.72 m) of supply and return line d. 50 feet (15.24 m) of underground line insulation e. Forced air furnace heat exchanger (radiator or coil) f. Domestic hot water tank heat exchanger (optional) Circulating pump g. h. Pipe fittings i. Two ball valves j. Approved rust inhibitor k. Thermostat I. Installation and Operation Instruction Manual Site Requirements 1. The Cozebum furnace must be Installed on a noncombustible floor pad, such as concrete or patio blocks. 2. There must be a minimum clearance between the furnace and any combustible material as follows: From top of furnace 60 inches (152 cm) From front of furnace 48 inches (122 cm) From side of furnace 6 inches (15 cm) From rear of furnace 48 inches (122 cm) From flue pipes 18 inches (46 cm) 3. Install the furnace in a location that best suits wind direction for your home and building(s) and neighbouring residents. Consult with an insurance provider to confirm acceptable furnace installation distance from all buildings. 4. The Canadian Standards Association requires a minimum 6 feet (L83 m) of insulated chimney in order to obtain the best draft in the furnace. 5. Installation of the Cozeburn furnace must be completed in accordance with local, state, provincial or federal building and fire codes which may differ from this manual. IMPORTANT: Contact an insurance provider prior to Installation to ensure that installation is in compliance with local insurance requirements and all terms have been met. COZEBURN INSTALLATION AND OPERATION MANUAL 9 INSTALLATION . ■!1llalllalelll!lal�lalPA1l1lJ Insulated Lines Water Lines Foundation Dimensions Trench for Underground Pipes 1. The furnace should be installed on ..,1: The water a concrete pad.* Slope the pad 1/2". lines must (1.27: cm) towards the front of the furnace be properly in order to drain off any condensation insulated that may accumulate in the ash tray. to minimize *For furnaces without legs an option is to heighten the ', heat loss. Ask pad for easier loading and ash tray removal. your dealer 2. If the soil is somewhat unstable, a good bed of crushed rock or a grade beam, will help prevent.: the furnace from shifting. for the right.: • underground •• water line insulation.' Dig a trench; ideally 24" (61 cm) deep* and :12" (31 cm) wide, and make as level as poSsible'to avoid damage to the tubing:::`, * Trench should .be at least 46.': (91. driveways. The water lines should be a minimum "of (2 cm) inside dimensions*; rated and approved for ::.. :use with high temperature water-. antifreeze *Size of water lines depends on .distance; check : with a qualified heating professional .to determine; the line. 'size necessary to meet thedemands°of your specific application. 4 Identify each water ..line glearly, in -; order• correctly locate the hot and returi lines A a: in 4 49 64 250MS cm 10 124 163 in 55'. . 13 140 208 s 15 10 25 10.. 2 31 .5... Lay down' 14-2 underground wire:. approved .far • underground Installation. Obtain the.: required electrical permit and confirm local.... electrical'.. code requirements priiarto.installation: .` 10 COZEBURN INSTALLATION AND OPERATION MANUAL r r INSTALLATION Installing the Furnace We recommend that the furnace be installed by a qualified installer. Position furnace on pad. Note: Lift only by top lifting hook or bottom forklift guides. Use caution! Furnace is heavy. Once the unit has been placed into position, remove the back cover and the light globe from the firebox and install. Type "A" furnace requires a tight silicone seal around the base to keep out rodents, etc. The furnace is now ready to hookup the heater to the underground water lines. 1. Install shut off valves on all lines attached to the furnace to prevent loss of water during maintenance and repairs. Fittings and valves to be attached to the furnace should either be stainless steel or brass. 2. IMPORTANT: A spark arrester must be installed if the Cozeburn Outdoor Wood Burning Furnace is used in a high fire risk area. 3. The water circulating pump must be mounted in the hot supply line several feet below the top of the furnace water level to minimize air lock problems, see Figure 1, 2, or 3. IMPORTANT: Pump must always be in lowest part of the line system and horizontal with the ground, see Figure 4. Figure 1 - Ideal Set Up Water level Ground level Building to be heated Pump may be located In the hot water supply line inside this building Figure 2 411N16 Water level Ground level Building to be heated Pump may be located in the hot water supply line inside this building Figure 3 Water level Not less than 2rt(.61m) Ground level When water Is to be pumped uphill, pump must be located In the hot water supply line at the amaze COZEBURN INSTALLATION AND OPERATION MANUAL 11 INSTALLATION Typical Installation Figure 1 Heat exchanger Circulating pump Under floor heating pipes Return line `Mixing valve .-Existing furnace Insulated return pipe Cozebum Insulated supply line Filter Pump Hot water tank Side arm heat exchanger 12 COZEBURN INSTALLATION AND OPERATION MANUAL INSTALLATION Figure 2 To furnace 41 --- From From furnace -► .a:Bleeder valve t Return line Outdoor furnace circulating pump Hookup to Existing Heat System (Water to Air) 1. Install the circulating pump on the supply line and ensure that the pump's motor is in a horizontal position. 2. Install the heat exchange radiator in the hot air plenum of the forced air furnace, Figure 2, according to the manufacturer's instructions, taking care to seal all joints and holes. 3. After installing the heat exchanger to the forced air furnace system, check to ensure that the air flow is the same as specified by the manufacturer of the existing heating system. The furnace fan should not generally need to be changed in order to accommodate the addition of the heat exchanger. Belt Driven Hot Air Fan 4. Pulleys on motor and blower may have to be adjusted to get the proper rate of air flow. Direct Drive Fan 5. Adjust the motor speed to obtain the correct air flow. Thermostat 6. Install a second thermostat to allow the blower to cut in separately from the furnace. 7. The existing thermostat should be set several degrees lower than the new thermostat. This will allow the regular system to cut in, should the Cozeburn run out of wood and the temperature drop below the second setting. IMPORTANT: Have a qualified electrician check to ensure that these changes do not cause the electrical motor to be overloaded. Any modification to the existing forced air heating system must be made In accordance with the manufacturer's specifications and performed by qualified, licensed personnel in accordance with local building codes. 111111111111111 Under Floor Heat 1. A 24 V thermostat with relay should be used in a house. For garage or shop, wire pump through an in-line thermostat. 2. Each zone can be manually adjusted with the ball valves on the supply header. 3. Adjust mixing valve to run supply water temperature between 110' F - 120' F (43' C - 49'C) in concrete floor installation. Supply header Return header Restrictor valves Mbdng valve Circulating pump Figure 3 From outdoor furnace COZEBURN INSTALLATION AND OPERATION MANUAL 13 INSTALLATION Side Arm Installation COLD Y MIXED WATER WATER Figure t MPERING VALVE Hot water Used for bleeding air To heating system Supply. -, • from furnace • SYMBOL.INDEX: `PUMP'. DQ BALL VALVE.: THERMOMETER' `.. ° BOILER DRAIN; .. c5 TEMPERING OR MIXING VALVE Have a .` qualified electrician and plumber check to ensure,. all connections ' to The furnace:' are in accordance with the:: manufacturers specifications land performed by qualified, licensed personnel in accordance . with local building codes. WATER HEATER Water heater drain NOTE: Keep bottom loop (and side arm) as low as possible:, Optional Heat Exchanger Stainless. Steel Water to Water Heat Exchanger, Figure 2, can be used in place of a side arm. To top of hot water tank Figure 2 �To heating system Hot water in from furnace From bottom of hot water tank 14 COZEBURN INSTALLATION AND OPERATION MANUAL r r INSTALLATION Auxiliary Heat (Water to Water) Figure 3 r Water to water heat exchanger Existing hot To baseboard, in -floor water boiler radiator, etc. -4 – Return Cozeburn —0" Supply A regular furnace system is left intact and Note: Whichever furnace is to be the standby automatically cuts in when the Cozeburn Outdoor unit, the aquastat on that furnace is to be set Wood Furnace runs out of wood, Figure 3. lower than the main furnace. Hookup with Existing indoor Furnace (Water to Water Plate Heat Exchanger) Figure 4 Existing water/air heating coil w cc Expansion tank with fill/ drain valves and back flow prevention valve Cozebum S Circulating Pump 0. a z U) COZEBURN INSTALLATION AND OPERATION MANUAL 15 INSTALLATION Baseboard un armee. Thermostat . Line 1 ,Line 2 `3 way zone valve From outdoor furnace ® Outdoor furnace circulating pump: Common Header Set Up Pump can ..be wired through an in-line thermostat: Each zone can be manually adjusted. . with .the( ball valves on the supply header. Adjust mixing valve to. run. entering water temperature between:110°F.:120°F (43°C - 49°C) in concrete floor Installations...•::. Return header • Alr vent Temperature gauge Return to boiler Supply header Circulation pump 16 COZEOURN INSTALLATION AND OPERATION MANUAL OPERATION Figure 3 Vent openin a-.4ncEvi.;r:... �r.:::i.wrL•r.;70"y Yv r•. ��rr:vry �crivv q!vuSv�Y2 r�'S ,dh, £�`a:Trir:,:.,,?slrr ....qr; rfr•:;; IMPORTANT: 1. Use only soft, clean, filtered water in the Cozeburn. Add Pro -Fab approved water treatment to the water to prevent corrosion (available from your Cozebum dealer). 2. Add approved antifreeze to the water chamber to prevent freezing should the furnace and the pump shut down due to a power failure or other cause. For amount of antifreeze to add follow instructions on the container. Use only environmentally friendly, propylene glycol based, low toxicity, non petroleum based antifreeze designed for use In hot water furnace systems. Available from your Cozeburn dealer. First Fill 1. To fill the furnace with water from the inside of the building being heated, install a plumbing "T" in the return or supply line complete with a check valve and boiler drain, see Figure 4. 2. Attach a garden hose, with two female ends, from the water supply to the filler valve. 3. Isolate the furnace by closing off supply and return valves securely at the back of the furnace. IMPORTANT: The Cozeburn may need to be drained of its contents at some time in the future. Be sure to place the line fill/drain assembly in a location where water can easily be drained and will not cause damage to the surrounding area. 4. Turn on the water to pressurize the line system and check for leaks in the system. DO NOT PRESSURIZE THE FURNACE. 5. CHECK ALL LINES AND CONNECTORS FOR LEAKS. 6. After checking for leaks in system, open the SUPPLY valve at the furnace and let water run for 2 minutes and then close it. 7. Now open the RETURN valve at the furnace and let water run for 2 minutes and then close it. 8. Repeat above procedure 3 to 4 times during filling of the furnace. Alternating between lines will ensure that most of the air is bled from the system. 9. When the Cozeburn is full, shut off water and close the in-line filler valve and disconnect the garden hose. 10. Mix Pro -Fab approved water treatment, with one to two gallons of warm water and pour through vent opening, Figure 3. Maintaining Proper Water Level When water level is low, the Cozeburn may be filled or topped up through the vent opening, Figure 3. COZEBURN INSTALLATION AND OPERATION MANUAL 17 OPERATION Starting the Fire in the Outdoor Hot Water Wood Furnace Once the Cozeburn has been properly installed, all connections checked thoroughly and the water system is filled to the proper level, the unit is ready for starting a fire. 1. Place some dry split kindling at the back of the firebox, on top of some paper, and ignite. 2. Once the kindling begins to burn, add large pieces of wood until the fire burns briskly. Do not fill the firebox of the furnace to capacity until the water in the furnace is hot. 3. Only put enough wood into the furnace as may be burned during a twelve hour period. A small intense fire burns cleaner and is preferable to long smoldering fires which may create excessive creosote deposits in the chimney... CORRECT Wood will burn cleaner and better if exhaust passage is kept open. INCORRECT Tightly packed wood will reduce airflowfor proper combustion. DO NOT USE THE DOOR AS A LEVER TO FORCE WOOD INTO THE FIREBOX! Note: The Cozeburn has been pressure tested at the factory for water leaks. Some condensation may be observed in the firebox while the furnace is heating up after the water has become completely cold. 18 COZEBURN INSTALLATION AND OPERATION MANUAL r r r r i OPERATION OUTDOOR BEST BURN PRACTICES 1. Read and follow all operating instructions supplied by the manufacturer. 2. FUEL: Use only those fuels recommended by the manufacturer of the unit. Never use the following: trash, plastics, gasoline, rubber, naphtha, household garbage, material treated with petroleum products (particle board, railroad ties and pressure treated wood), leaves, paper products, and cardboard. 3. LOADING FUEL: For a more efficient burn, pay careful attention to loading times and amounts. Follow the manufacturers written instructions for recommended loading times and amounts. 4. STARTERS: Do not use lighter fluids, gasoline, or chemicals. 5. LOCATION: It is recommended that the unit be located with consideration to prevailing wind direction. • Furnace should be located no less than 100 feet from any residence not served by the furnace. • If located within 100 feet to 300 feet of any residence not served by the furnace, it is recommended that the stack be at least two feet higher than the peak of that residence. 6. Always remember to comply with all applicable state/provincial and local codes. Chimney Height Installation Scenario :.rtirnrey height-•- --•-- Res ir.= nu"sl1 L Id Le 2 fes: a bc: _ •oc= I ino . aereeo oy finace �!er.In:-nrF r n- ser: ed G; 'v 'race PBA Hearth. Patio & Barbecue Aeaoeiatinn OUTDOOR FURNACE MANUFACTURER'S CAUCUS COZEBURN INSTALLATION AND OPERATION MANUAL 19 MAINTENANCE During Heating Season Inspect the vent (item 20, page 8) periodically for any blockages. Always ensure that the vent cap fits loosely in order to prevent the unit from becoming pressurized. The Cozeburn is designed as an "Open to Atmosphere" system and should never. be • under pressure! The ash tray must be checked weekly and emptied as necessary. Ensure that the ash tray is securely closed after each cleaning. Adjust the latch if necessary. Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible material, pending final disposal. Other waste should not be placed in the container with the ashes. Check the water level at least once a week to ensure the level is well above the "ADD" mark. Oxygen buildup causes corrosion inside the water system. Keeping the water reservoir completely full avoids oxygen buildup, especially during the summer months when the furnace is not in use. . Check the door gasket to ensure an air tight fit. 5. Turn off power. 6. Check and clean the damper cover to prevent creosote buildup. A creosote buildup could cause the damper to seize, .:causing the circuit breaker to disengage. 7 Check and clean the chimney at least once per month. A buildup in the chimney will cause a poor draft. `. 8. Cover plates and guards must be in place at all times, except during maintenance and servicing. End of Heating Season 9. - Thoroughly clean the furnace :of any creosote • or ash buildup. Hardened creosote or ashes are easier to be removed when furnace is still warm. 10. Check to ensure there is no moisture in any part of the inside of the firebox, or in the ash tray. 11. Cover and seal the chimney to prevent any rain or moisture from entering the firebox chamber while not in use. 12. Ensure the water reservoir is full during the non -heating season to prevent corrosion inside the water jacket. 13. Add a sufficient amount of Pro -Fab approved water treatment to the water system each year after the heating season. Operate the water circulating pump for 24 hours after adding water treatment to ensure proper mixing of the water treatment with the water.. 14. A water sample must be drawn 30 days after purchase of the unit and forwarded to your dealer for testing. Maintain the results of this test on file. Thereafter, draw a water sample once a year and forward to your dealer for testing...; Water properly treated with Pro -Fab approved water treatment should be between 8.8 and 11.0, a nitrate level between 730 and 1460 ppms as NaNO2, and a conductivity mustbe less than or equal to 4000 mmhos. If the pH or nitrite level is low, more Pro -Fab approved water treatment should be added. if the level of conductivity is too high, 1/2 the water in the unit should. be drained and replaced with fresh water. Falling to use Pro -Fab approved water treatment in accordance with the Installation and Operation Instructions will void the warranty. See your dealer. for authorized supplies. It Is the responsibility of the owner to maintain yearly water sample results on file. 20 COZEE3URN INSTALLATION AND OPERATION MANUAL J r r r r MAINTENANCE Cleaning the Ash Tray 1. The ash tray must be checked weekly and emptied as necessary. Ensure that the ash tray is securely closed after each cleaning. 2. To avoid a buildup of ashes in the firebox, stir ashes daily to allow them to fall through to the ash tray. Keep ashes away from the air injection tubes. Caution: Ashes should be removed when fire is out, do not remove burning material or glowing embers. 3. Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible material, pending final disposal. Other waste should not be placed in the container with the ashes. Ashes may stay hot for a long time and could cause a fire. Power Outages The Cozebum furnace, unlike a gas or oil fired appliance, does not stop generating heat when the power is interrupted even though the blower automatically shuts off causing the fire to die down. As a result the heat transfer fluid in the furnace may over heat and boil off through the vent. When power resumes be sure to check the fluid level. COZEBURN INSTALLATION AND OPERATION MANUAL 21 REFERENCE .Operating the Digital Temperature Switch (DTS DTS Description The digital temperature switch is designed for:, many heating and cooling applications. The .probe.... emperature (Figure 1) is displayed on the bright 3 -digit, red light emitting diode (LED). The user is able to adjust the set point using the front keypad.. Theunit features a 16 amp; single pole, double throw (SPDT) relay'with the temperature display in •degrees Fahrenheit. DTS Physical Data Accuracy: ±1° Output: 16 Amp SPDT relay Supply voltage: 110 V Front panel protection: NEMA 4 (Ip65) Display: 3 -digit, red. Digit heigh DTS Programming Press SET; SP text will appear on the display, Press SET again.` The real value is shown' on the display. 127cni) DTS Wiring Diagram The value can ..be modified with`. the UP and DOWN arrows. .. Press. SET to enter,newvalues: Press SET and DOWN at the same time .to.. exit programming or wait one minute arid the. display will automatically exit the programming mode: `NOTE: Only the temperature .. setting.' programmable. All other settings are locked:: DTS Maintenance/Repair -After final installationof the ,digital temperature switch, no routine :maintenance:, is.required; `This. device is not field repairable and should be;returned' to the factory ; if .recalibration: or : other. service: i required. ny . modification or tampering with`. settings of the DTS will void the warranty: DTS Display Messages n normaloperation, the probe temperature .will be shown on the display. in case of an alarm or error; the following messages will be shown:: Memory error -`� Short-circuit probe error» = Open probe error 22 COZEBURN INSTALLATION AND OPERATION MANUAL r r f r REFERENCE Outdoor Hot Water Wood Furnace Wiring Diagram - 250MS & 450MS 1. Love Controller 2. Light Switch 3. Damper Switch 4. Light 5. Probe 6. Snap Disc 7. Circuit Breaker 8. Solenoid 9. Blower 10. Junction Box Black Power Line White Natural Line Line Line Ground 110 Volts AC COZEBURN INSTALLATION AND OPERATION MANUAL 23 REFERENCE Furnace Reference Cha When ordering parts please use this reference chart. I lOD glL Ai18ER :?l} MSI . i., 4 5::.. . ;::E> Warranty 10 Years 10 Years • Capacity - Imperial gallons 125 250 - U.S. gallons 150 300 - Litres 568 1,136 Options Front Draft Forced Yes Yes Natural Optional Optional When ordering parts be sure to sped 1. Serial Number 2. Model Number 3. Applicable Option Standard Forced Draft Door Optional Natural Draft Door Solenoid and . damper lid regulate air to blower. 1.70 24 COZEBURN INSTALLATION AND OPERATION MANUAL REFERENCE Furnace Specifications ;FURNACEMODEL .2 Units in cm in cm Total Width 49 125 57 145 Body Width 47 119 55 140 Total Length 80 203 97 246 Body Length 59 150 77 196 Chimney Size 8 15 8 20 Wading :Dcor$1±e_:., in 20 x 20 20 x 24 cm 51 x 51 51 x 61 EireboxS H 30 76 36 91 W 33 84 45 114 L 42 107 60 152 Water .0 Imperial gallons 125 250 U.S. gallons 150 300 Litres 568 1,136 Heating:Area Sq. ft* 4,000 8,000 Sq. m* 372 743 Shipping Weight lbs 2,000 3,200 kg 907 1,451 Note: Weights and measurements may vary slightly. * May vary according to home and climatic conditions. COZEBURN INSTALLATION AND OPERATION MANUAL 25 r TROUBLESHOOTING Furnace Troubleshooting :.2'; :•f �, P�F30�BC.E�ll1 �u._.__ , _. _._ �ri ;:5 .) i• is J. :F%. ,����$SIBE�C�U .__ __...., .. W;,':_..., c I� 1 Iwo:. Damper does not open. : High limit switches may be shut off because the water temperature is higher than aquastat setting permits. Wait for the water to cool down. Circuit breaker may have disengaged due to creosote buildup on and around the damper causing the damper cover to stick. Clean damper area. Push reset button on breaker (see #3 page 8). No electricity. Check your power supply. Damper solenoid defective. Replace. Hot water is not reaching the building. Water level is low. Fill system to proper water level. No water circulating. No power to pump. . Faulty pump - fix or replace pump, or replace cartridge. Air in water lines. Bleed lines to release water and ,reprime the circulating pump. Little or no draft. Furnace is cold.: .. Start small fire with dry kindling before reloading furnace with firewood (see page 18). Chimney is plugged. Clean regularly, as per instructions in the manual. Furnace overheats and boils. Main door has been left open. Close door. Main door and/or ash tray gaskets are leaking. Replace gaskets or adjust latches and/or hinges. Circuit breaker disengages. • Damper is sticking (solenoid overloaded). Clean damper thoroughly. Blower not functioning (forced draft only). Clean and oil blower. Solenoid rattles during operation. The alignment between the solenoid. and the lift tab is out. Loosen all four adjustment screws and realign the solenoid until it operates smoothly. Extensive condensation and creosote buildup. Differential on aquastat not large enough, unit cuts in too often. Increase differential settings. Wet or poor quality of wood. Use dry seasoned. firewood only., Ash tray is sticking. Creosote or condensation buildup. Oil drawer slides and edges as required and remove tray more often. 26 COZEDURN INSTALLATION AND OPERATION MANUAL r r r r r TROUBLESHOOTING Digital Controller Troubleshooting COZEBURN INSTALLATION AND OPERATION MANUAL 27 The water overheated and boiled over and now after refilling it, the water temp is below operating range but there is no power coming through to the damper (and blower). The High Limit Switch (snap disc) has tripped the circuit, This high limit switch is designed to reset automatically when the temperature drops down to approximately 130°F (54°C). When the snap disc function is defaulted the power should be restored. The demand for heat is on with sufficient wood in the firebox but no power is coming to the damper (and blower). The damper lid may be stuck causing the Reset Switch to pop out. Loosen the damper lid and push in reset button. . While reloading the firebox there seems to be an excessive amount of smoke coming out of the door (more than usual). The draft is restricted due to creosote buildup in the chimney stack. Clean the chimney stack, most buildup tends to be at the top of the stack. COZEBURN INSTALLATION AND OPERATION MANUAL 27 oze ur Since 1989:.= rZ 10 Year Limited Warranty Warranty service may only be performed by Pro -Fab Industries or a Pro -Fab Authorized Cozebum Furnace Dealer or a Pro -Fab Authorized Cozeburn Furnace Service Centre. PRO -FAB INDUSTRIES INC. WARRANTY Pro -Fab Industries Inc. (hereinafter called "Pro -Fab") warrants to the original owner of the Cozeburn Furnace (hereinafter called the "Cozebum") the following: A two (2) year warranty on the workmanship of the furnace and workmanship on all parts manufactured by Pro -Fab, from the consumer date of purchase, and excluding normal wear items such as (but not limited to) the door gasket, fire brick (if appli- cable), insulation, exterior finish and chimney. A one (1) year warranty for any labour required for any repair or • replacement of the furnace or parts from the consumer date of purchase based on_ Pro-Fab's predetermined labour rates and al- lowable hours.. . A limited pro -rated warranty coverage (which includes the one (1) year labour coverage at Pro -Fab rates and hours as stated above) for a defective firebox and water jacket only, based on the follow- ing pro -rated scale from the consumer date of purchase: • Years one (1) and two (2) —one hundred percent (100%) coverage; . • Years three (3), four (4) and five (5) — sixty percent (60%), coverage; - • Years six (6) and seven (7) • — thirty percent (30%) coverage; • Years eight (8) and''nine (9) - fifteen percent (15%)'. coverage; • Year ten (10),—ten percent (10%) coverage: Absolutely no warranty is provided after ten (10) years from_ the consumer date of purchase.' . Note: All parts NOT manufactured by Pro -Fab carry their own manufacturer's warranty. The owner Is responsible for all costs necessary to replace those parts unless covered by. the appli- cable manufacturer (except for the one (1)' year labour cover- • age at Pro -Fab rates and hours as stated above). •• The above warranties are based on the following factors:, Pro -Fab reserves the right to repair or replace at its discretion any defective part or furnace, in whole or in part. . Use of Pro -Fab approved water treatment.. IMPORTANT: Pro Fab approved water treatment is available , from your local dealer or service centre and must be used and validated for • warranty coverage. The pH balance must remain between 8.8 and 11.0, the nitrite level must remain between 730 and 1460 - ppm as NaNO2, and conductivity must be less than or equal to. , 4000 mmhos. A copy of the invoice itemizing the purchase of approved water treatment will be required as proof 'of mainte- nance in the event of a warranty claim. All laboratory reports must be kept as proof of maintenance (see page 20 of your. Installation and Operation Instruction Manual). . . All instructions in the Cozeburn Installation' and Operation In- • struction Manual must be followed. • • The Warranty Registration and a copy of the, original bill (in- ' voice) in'voice) must be forwarded to Pro -Fab within thirty (30) days, of the consumer date of purchase to validate the warranty. Pro -Fab will not be responsible or liable for any of the following: a) If warranty work requires removal or replacement of all or a part of the furnace, Pro -Fab is not responsible for the cost of plumbing, freight, permits, removal or disposal of damaged furnace or parts, replacement of water or additives, labour after the one (1) year war- ranty coverage expires, or any cost other than the warrantied re- placement part itself or the furnace; b) The care, maintenance and safe operation of the Cozeburn Furnace, which is the responsibility of the owner of the furnace; -c) Any accidents, injury, damage or loss incurred due to a heating system failure; d) Any accidents, injury, damage or loss incurred due to faulty installation, operation or maintenance; e) Any cost incurred for replacing or repairing of parts not manufactured by Pro -Fab which carry their own manu- facturers warranty (except for the one (1) year labour coverage at Pro -Fab rates and hours as stated above); f) Any out-of-pocket expenses, alternative accommodations or foss of revenue due to defective parts or furnace; g) Performance problems caused by improper sizing of the furnace, vent connection, or air openings; h) Damages; malfunctions or failures resulting from the use of any attachment not authorized by Pro -Fab; i) Units installed outside the continental United States, Alaska, or the provinces and territories of Canada without prior approval from Pro -Fab; j) Units with their safety certification labels removed; or k) Damages, malfunctions. or failures caused by force majeure, abuse, accident, fire, or acts. of God. . Any available warranty will be'vold if:. a) Maintenance 'procedures are not followed (see Installation and Operation Instruction Manual page 20); b) Water treatment and proper additives are not used as specified in the Installation and Operation Instruction Manual (see page 20); c) The Cozeburn Furnace has been altered in any way; d) Any material other than Pro -Fab approved fuel has been used; e) Any instruction given in the Installation and Operation Instruction Manual which has not been followed including during installation or regular maintenance: or f) Any claim made under the warranty for a person other than the original owner. There are no other warranties, expressed or implied, by Pro -Fab or its Authorized Cozeburn Furnace Dealers or Authorized Cozebum Furnace Service Centres regarding the Cozeburn Furnace except the warranty expressed herein. ANY IMPLIED WARRANTIES, IN- CLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE APPUCABLE WARRANTY PERIODS SPECIFIED ABOVE. PRO-FAB'S SOLE UABILITY, WITH RESPECT TO ANY DEFECT, SHALL BE AS SET FORTH IN THIS LIMITED WARRANTY, AND ANY CLAIMS FOR IN- CIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED. .:Issue Date: May 2012. Part. No: 815378R03; No person is authorized to bind Pro -Fab to any other warranty whatsoever. Pro -Fab reserves the right at any time to make changes or improve- ments to the design, materials, or specifications of the Cozeburn line of furnaces or parts without thereby becoming liable to make similar changes in the furnaces or any of its parts previously manu factured. P01 -AB INDUSTRIES INC Manufactured by: Pro -Fab Industries Inc. Printed in Canada JW0512 ri t.